Normal probe
2.5mm/5mm/8mm/10mm
DUL : Dual probe (X/1H/2H)
BBO : Broad band probe (15N-31P/1H/2H)
BBFO:Broad band probe (15N-31P/19F/1H/2H)
CINDP probe
|
 |
Inverse probe
1mm/2.5mm/3mm/5mm/8mm
SE I : Inverse selective probe (X/1H/2H)
BBI : Inverse Broad band probe (15N-31P/1H/2H)
TXI : Inverse Triple resonance probe (15N/13C/1H/2H)
TBI : Inverse Broad band Triple resonance probe(BB/X/H/2H)
QXI: Inverse Quadruple resonance probe (15N/13C/31P/1H/2H)
QNI: Inverse Quad Nuclear probe (15N-13C-31P/1H/2H)
|
 |
Cyroprobe:
Enhance sensitivity for 3-4 times!!
SEF : Selective Fourine Probe(19F/1H/2H)
DCH : Dual probe (13C/1H/2H)
TXI : Inverse Triple resonance probe(15N/13C/1H/2H)
TCI : Inverse Triple resonance probe , 13C preamp cooled(15N/13C/1H/2H)
QNP : Quad Nuclear probe (15N-13C-31P/1H/2H)
10mm DUL : 13C/1H/2H
micro imaging probe
Cryo Fit for LC-NMR
|
 |
Cyroprobe Prodigy:
Enhance sensitivity for 2-3 times!!
TCI : Inverse Triple resonance probe (600 MHz 15N/13C/1H/2H)
BBO : Broad band probe ( 400MHz , 500 MHz , 600 MHz) |

|
1mm micro
probe
Enhance mass sensitivity form 4 times
TXI : Triple resonance probe(15N/13C/1H/2H)
|

|
Fow
Probe:
30ul/60ul/120ul/200ul
SEI: Inverse selective probe (X/1H/2H)
DSP: Dual switch probe (F-H/2H ,H-F/2H)
TXI: Triple Resonance probe(15N/13C/1H/2H)
|

|
HR-MAS High resolution Magic Angle Spectroscopy
SEI : Inverse selective probe(13C/1H/2H)
SEI : Inverse selective probe (31P/1H/2H)
DUL: Dual probe(13C/1H/2H)
DUL: Dual probe(3P/1H/2H)
TXI: Triple resonance probe(15N/13C/1H/2H)
TXI: Triple resonance probe(13C/31P/1H/2H) |

|
CP/MAS probe
1.3mm/1.9mm/2.5mm/3.2mm/4mm/7mm
DR: Double Resonance probe(X/H)
Triple: Triple Resonance probe (X/Y/H)
TriGamma: Two broad band Triple resonance probe(X/Y/H)
Wide range of temperature range(VTN,WVT,DVT) |
 |
Micro
image probe
Micro5 (For Standard Bore magnet , 1H or X):
Gradient strength: 288G/cm
ID/OD: 19/40mm
RF coil diameter: 10 mm
Micro2.5 (For Wide Bore magnet ,1H or X):
Gradient strength: 150G/cm
ID/OD: 40/72mm
RF coil diameter: 2-30mm
MicroMouse2.5 : Fix Birdcage RF coil(30mm)
Mouse to 30 g
Micro2.5 AHS : RF coil up to 25mm
Mouse to 30 g
Mini0.5 (AHS)(For Wide Bore magnet ,1H or X)
Gradient strength: 0.5G/cm/A
ID/OD: 52/72mm
RF coil diameter: 38mm , 34mm(AHS)
Mini0.36/(AHS)( For Super Wide Bore magnet ,1H or X)
Gradient strength: 0.36G/cm/A
ID/OD: 85/115mm
RF coil diameter: 64mm , 60mm(AHS)
|
 |
Diffusion probe
Diff* : Single or double resonance , Normal or Inverse
Sample tube diameter : 5mm/8mm/10mm(Single resonance)
5mm/8mm(Bouble resonance)
Diff*L: Triple Resonance (double resonance +2H, 5mm)
Maximum Gradient strength
Diff30 : 1710G/cm(Z)
Diff50 : 2850G/cm(z) , For Wide Bore magnet only.
Micro5: 300G/cm(X/Y/Z)
|

|
Wideline
Solid
probe
5mm/7.5mm/10mm
Wideline probe : 2H or selective RF insert
BIO PE: X/H or X/Y/H
Flat coil version |
 |
ATM
Automic Tuning and Matching
Attached at bottom of the probe , tuning and matching was done
by software manually or fully automatic for ICONNMR . Avoid
misadjust by the operator
Suit for any probe including cryoprobe |